The most important objective of all sorts of building ventilation is to supply appropriate volume of air to the zone where people stay, as well as oxygen contained therein to provide comfortable, hygienic conditions of stay for build-ing users.
OnyX product line has been designed with the thought of operation in cli-matic conditions. OnyX recuperators care for the comfort in rooms by as-suring heat recovery from exhaust air.
A new generation counter-flow heat recovery exchanger with reduced flow resistance requires less electrical power and ope-rates at lower noise levels that the traditional solutions. It is made entirely of highly durable plastics. The heat exchanger provides a high internal airti-ghtness, which prevents mixing of the fresh air supply with the extracted air. The heat reco-very system features a 100% automatic by-pass system for free-cooling.
Maximum air flow (100 Pa) | m3/h | 877 |
Power consumption by fan drive (rated) | W | 338 |
Preliminary heating coil, type, capacity | W | 2000 W / 230V AC/50Hz |
Rated voltage | 230V AC/50Hz | |
Type of fuse | C6 overcurrent circuit breaker | |
Dimensions | mm | 565 x 1063 x 1477 |
Specific power input | W/(m3/h) | 0,27 |
Connection diameter | mm | 315 |
Weight | kg | 128 |
Filter class | – | ISO Coarse 60%(G4) |
Filter size | mm | 2x 400x180x25 |
Protection level | – | IP 40 |
Insulation class | – | I |
Environment conditions in technical room | ||
Operating temperature range | ºC | 5-45 |
Permissible humidity | % | 25-90(no condensation) |
By-pass | – | 100%, Standard |
Control system | – | Frapol SMART controller |
Maximum air flow (100 Pa) | m3/h | 2692 |
Power consumption by fan drive (rated) | W | 2100 |
Preliminary heating coil, type, capacity | W | max. 6000 W/3x400V AC/50Hz |
Rated voltage | 230V AC/50Hz | |
Type of fuse | C6 overcurrent circuit breaker | |
Dimensions | mm | 2046 x 486 x 1790 |
Connection diameter | mm | 760×360, 940×360 |
Weight | kg | 225 |
Filter class | – | ISO Coarse 65%(G4) |
Filter size | mm | 760 x 400 x 100 |
Protection level | – | IP 40 |
Insulation class | – | I |
Environment conditions in technical room | ||
Operating temperature range | ºC | 5-45 |
Permissible humidity | % | 25-90(no condensation) |
By-pass | – | Standard |
Control system | – | Frapol SMART controller |
Maximum air flow (100 Pa) | m3/h | 990 |
Power consumption by fan drive (rated) | W | 1050 |
Preliminary heating coil, type, capacity | W | max. 1000 W |
Rated voltage | 230V AC/50Hz | |
Type of fuse | C10 overcurrent circuit breaker | |
Dimensions | mm | 1142 x 345 x 1893 |
Connection diameter | mm | Ø250 |
Specific power input | W/(m3/h) | 0,56 |
Weight | kg | 152 |
Filter class | – | ISO Coarse 65%(G4) |
Filter size | mm | 445 x 280 |
Protection level | – | IP 40 |
Insulation class | – | I |
Environment conditions in technical room | ||
Operating temperature range | ºC | 5-45 |
Permissible humidity | % | 25-90(no condensation) |
By-pass | – | Standard |
Control system | – | Frapol SMART controller |
Maximum air flow (100 Pa) | m3/h | 1498 |
Power consumption by fan drive (rated) | W | 1060 |
Preliminary heating coil, type, capacity | W | max. 4000 W / 230V AC/50Hz |
Rated voltage | 230V AC/50Hz | |
Type of fuse | C6 overcurrent circuit breaker | |
Dimensions | mm | 1670 x 445 x1700 |
Connection diameter | mm | Ø315 |
Weight | kg | 172 |
Filter class | – | ISO Coarse 65% (G4) |
Filter size | mm | 592 x 287 x 200; 592 x 287 x 300 |
Protection level | – | IP 40 |
Insulation class | – | I |
Environment conditions in technical room | ||
Operating temperature range | ºC | 5-45 |
Permissible humidity | % | 25-90 (no condensation) |
By-pass | – | Standard |
Control system | – | Frapol SMART controller |